Ajax TOCCO Toccotron AC Spécifications Page 31

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 30
OM-229 158 Page 27
Press the Run button to resume program operation and the yellow indicator LED will illuminate.
Press the Stop button to end the program.
SECTION 7 MAINTENANCE
7-1. Routine Maintenance
! Disconnect power
before maintaining.
Maintain more often
during severe conditions.
= Check = Change = Clean = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
3
Months
Section 4-8
Damaged or Unreadable
Labels
Output Bus Bar Con-
tacts
Ground Sense Lead Re-
ceptacles
Operator Interface Over-
lay
Cracked Cables
Every
6
Months
Section 9-8
Inside Unit
Vue de la page 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 51 52

Commentaires sur ces manuels

Pas de commentaire